Before you upgrade or retrofit an existing textile inspection system, check what the system now has to do and which part of it stops it from doing that. Then test each part against the new requirement: the frame and fabric path, the camera, lens and lighting, the encoder and trigger signals, image transfer and processing, the PLC and network, and the way operators receive and record results. The same checks apply wherever fabric is inspected in textile manufacturing.

An older component can still be the right one to keep, and a newer one can still be the bottleneck, so the decision should come from tests on your own line. A camera interface standard makes new parts easier to connect, but it does not show that the whole system will meet the new requirement. With this textile inspection retrofit checklist, you can find the real constraint in your current setup, decide what to keep, test, upgrade or replace, and know what to validate and what to prepare before a system assessment.

What Problem Are You Actually Trying to Fix?

Name the problem in production terms before you look at any hardware. The usual reasons to upgrade are defects that the system misses, good fabric that it flags or stops for (false rejects), a new product or defect type, a faster line or wider fabric, and a new need to record and analyze defect data. Each of these points to a different part of the system, so the problem decides where the assessment starts.

Table 1. Common upgrade problems and where to start checking

Problem Where it often points First check
Defects are missed Image quality (resolution, contrast, lighting, blur) or the detection settings Find the missed defect in the stored image. If it is not visible there, start with the imaging chain; if it is visible, check the detection settings
Good fabric is flagged or stopped Uneven or unstable lighting, fabric texture, lint, detection thresholds Review the flagged images of good fabric and group them by cause
New product or defect type Lighting, optics and the detection model Run samples of the new product through the existing setup
Faster line or wider fabric Exposure time, camera line rate, field of view, bandwidth, processing time Calculate the required line rate and data rate and compare them with the current limits
New need for records and data Software, position signal, data export, operator interface Check what the system records today and whether it can export it with the roll position

Swipe to see the full table

The balance between missed defects and false rejects also shapes the upgrade. In a 2026 case study of a brownfield retrofit at a jeans manufacturer, the partner company gave priority to avoiding the incorrect disposal of normal fabric and accepted some missed detections during validation, because experienced manual inspectors also miss some defects [1]. Another plant could make the opposite choice, and the same hardware would then be tuned and tested differently.

Some needs are not visual at all. Fabric weight, strength, moisture, or a color difference that has to be reported as a number may need a dedicated instrument or a laboratory test, and a better camera will not provide it.

AI-Innovate’s process for upgrading an existing inspection system follows the same order: it reviews the current lighting, cameras, sensors, processing, controls and mechanical setup, and identifies the component that limits inspection before any upgrade is designed.

Which Parts of the Existing System Might Be Reusable?

In brownfield textile inspection, almost any part of the existing system might be reusable: the frame and fabric path, cameras and lenses, lights, the encoder and other sensors, the processing computer, the PLC and network, and the operator interface. Each part has to pass a test to be reused: it must meet the new requirement on its own and work with the other parts, old and new.

The same case study shows what reuse can look like. The existing fabric inspection machine had been used for manual inspection, so the researchers kept the machine and its fabric transport and added cameras across the fabric width, bar lights, a rotary encoder and counter to time image capture, an actuator to stop the machine when a defect was found, and a computer to run the detection model. They mounted the cameras and lights on a frame physically independent of the machine, so that its vibration would not degrade the images [1].

That project describes one machine at one plant, and another line needs its own checks. Figure 1 sets out what usually leads to each decision for the seven parts of a typical fabric inspection retrofit.

Comparison table showing how to evaluate textile inspection system components—including frame and fabric path, camera and lens, lighting, encoder and trigger, processing, PLC and network, and operator interface ,using four actions: keep, test, upgrade or replace.
Figure 1. Example assessment matrix: what usually leads to keeping, testing, upgrading or replacing each part. Illustrative only; it does not show the result of a real project.

Use the matrix as a textile inspection retrofit checklist. Start every part in the Test column, and move it to Keep, Upgrade or Replace only when a check on your line gives a clear answer. A part that passes on its own can still fail in combination, for example an existing camera that gives sharp images but uses an interface that the new software or computer does not support.

Is the Existing Imaging Chain Good Enough?

The imaging chain is good enough when it shows the smallest defect you need to find, with clear contrast, across the full fabric width, at real line speed, and keeps doing so over a full shift. A practical way to know is to capture real defects on the running line with the existing camera, lens and lights, then check whether each defect can be seen in the stored images.

Check these points:

  • Smallest defect and pixel size: divide the fabric width each camera covers by its number of pixels across the fabric to get the size of one pixel on the fabric. The smallest target defect has to cover enough pixels to be recognized; the number needed is confirmed in testing.

  • Field of view: the cameras together must cover the full width, including the edges, with some overlap between neighboring cameras.

  • Exposure and motion blur: at line speed, a long exposure smears a defect along the direction of travel. In one online system for measuring fabric color difference, motion blur was controlled by matching the exposure time to the line speed [2].

  • Lighting: check how even the light is from edge to edge, how stable it stays over a shift, and whether room light or daylight reaches the inspection area.

  • Viewing angle and optics: check the camera angle, focus, working distance and the condition of lenses and protective windows.

A higher-resolution camera does not always fix a missed defect. If the defect has low contrast against the fabric, smaller pixels still record low contrast, and the light, angle or background usually needs to change first. Higher resolution also means more data per meter of fabric, which adds load on the camera interface and the processing computer.

To compare the existing camera with a candidate on equal terms, use data measured and presented under EMVA 1288, a standard method for measuring and presenting the performance of machine vision cameras and image sensors [3]. If no such data exists for the existing camera, an image test on the line serves as the comparison.

If the test shows that lighting is the limit, the options include a different light type, angle or shielding, or engineered machine vision lighting designed around the defect and the fabric.

Line speed and fabric width set many of these limits, because they decide the exposure time, the camera line rate and how many cameras the width needs. The detailed imaging requirements at real line speed and fabric width follow from those two values. When a new fabric is the reason for the upgrade, the light, optics and detection settings need a fresh check as well, as described in inspection changes for different fabric types.

Can the Existing Processing and Camera Interface Keep Up?

The existing processing and camera interface can keep up if every image reaches the processing computer without loss and is analyzed before the result is needed, at full line speed and full width, with some margin. Check the data rate the cameras produce, the bandwidth of the interface, the processing time per image, and whether the software, drivers and hardware are still supported.

  • Data rate: for each camera, multiply the pixels per line by the lines per second (for area cameras, the pixels per frame by the frames per second) and the bytes per pixel. Compare the total with what the interface, network cards or frame grabbers can carry.

  • Processing time: measure the time from image capture to result while the line runs at full speed and full width, since single test images understate the load. In the retrofit case study above, the detection model was chosen partly for its low latency, because it had to keep up with the line speed [1].

  • Software and drivers: check that the camera drivers and inspection software run on a supported operating system, and that updates and spare parts are still available.

  • Timing of the result: if the system has to stop the machine or mark the fabric, the result must arrive before the defect passes that point.

Camera interface standards help with the connection. GenICam provides a generic programming interface for cameras, whatever interface technology they use, such as GigE Vision, USB3 Vision, CoaXPress or Camera Link [4].

GigE Vision, a camera interface standard built on Gigabit Ethernet, relies on GenICam to describe the features a camera supports. It has been revised several times, and only registered compliant products may carry its logo [5]. Check whether the existing camera is registered as compliant and which version of the standard it implements.

These standards make it easier for new software to find, configure and receive images from an existing camera. They do not show whether that camera resolves the defect, whether the link has enough bandwidth, or whether the computer can process the images in time. Each of those still needs a test.

If processing at the line turns out to be the limit, the options include a faster computer, edge AI deployment for inspection, or AI-Innovate’s industrial edge processing with AIxCore.

Can the Existing PLC, Encoder and Controls Stay?

The existing PLC, encoder and controls can stay if the inspection system can exchange the signals it needs with them, reliably and in time. These include a position signal for image timing, ready and fault status, and a way to pass each result to whatever acts on it. Whether that works depends on the free inputs and outputs, the communication protocols the PLC supports and whether its program can be changed, so the answer differs from line to line.

  • Free inputs and outputs: spare digital I/O, or room for an I/O module, for trigger, ready, fault and result signals.

  • Communication protocol: which industrial protocols the PLC and network support, and whether the inspection system can use one of them directly or needs a gateway.

  • Access to the PLC program: who owns the program, whether it can be changed, and whether its documentation still exists.

  • Encoder and trigger: whether an encoder already measures fabric travel, whether its signal can be shared, and whether it slips or loses counts. If there is none, a dedicated encoder can be added.

  • Result handling: what happens after a detection, such as an alarm, a stop, a marker, or a record tied to the position on the roll.

  • Operator interface and records: whether operators can see and confirm each detection, and whether defects are recorded with their position on the roll and can be exported for quality records.

Older equipment often makes this harder. A systematic review of legacy system retrofitting notes that early industrial networks were built on a variety of serial interfaces. As a result, legacy systems use a mix of protocols, many of them incompatible with newer ones, which creates demand for adapters, switches and gateways [6].

On newer systems, OPC UA for Machine Vision, the OPC 40100 series, gives standard information models for controlling and observing a vision system [7]. It helps only where both sides support it.

If the upgrade adds anything that stops the machine or connects to its stop circuit, include it in the plant’s machine safety review. Safety-related parts of control systems are designed and integrated under standards such as ISO 13849-1 [8].

Detailed design of control logic, networks, safety functions and reject handling belongs to the engineering phase. The checks above are usually answered during a technical assessment on site, because they depend on the actual PLC, program and wiring.

What Textile-Line Constraints Can Block a Retrofit?

Physical and operating limits on the line can make a fabric inspection retrofit hard or impractical even when the electronics are compatible. Check the fabric width and path, tension, flutter and vibration at the inspection point, space for cameras and lights at the needed distance, access for maintenance, the real line speed, and where the fabric can be stopped, marked or diverted after a defect is found.

  • Width and path: the full width, including the edges, has to pass flat through the inspection zone. A wider product may extend past the current field of view, and a narrower one moves the edges to a different place in the image.

  • Tension, flutter and vibration: fabric that lifts or flutters moves out of focus, and machine vibration shakes cameras mounted on the machine. A separate frame that does not touch the machine is one way to isolate the cameras and lights.

  • Installation space and working distance: cameras and lights need room at a fixed distance from the fabric, without blocking operators, guards or fabric handling.

  • Maintenance access: lenses, windows and lights need regular cleaning, and parts need to be replaceable without taking the setup apart.

  • Real line speed: measure the actual speed range, including acceleration, slowdowns and stops, in addition to the nameplate value.

  • Action after detection: the distance between the camera and the point where the fabric can be stopped, marked or cut sets how much time the system has to respond.

Vibration can still affect results after measures are taken against it. One online fabric color inspection system included an anti-vibration stabilizing unit, and its authors still list mechanical vibration among the limitations of their production line trial [2].

These constraints also differ by process stage, which is why planning textile inspection on existing production lines starts from where a defect becomes visible and where the line can still act on it.

When Is Replacement Better Than Reuse?

Replacement is the better choice when testing shows that a component limits the new requirement and cannot be improved with reasonable effort, or when it can no longer be supported. Each reason should be backed by a test result or a confirmed end of support, and age alone is not one of them. Typical cases:

  • The fabric path cannot hold the fabric steady at the camera position, even with an independent mount or an extra support roller.

  • The camera cannot resolve the smallest target defect at full width and speed, even with a different lens or more cameras.

  • The lighting cannot give stable, even contrast for the target defect, even after changes in angle, type or shielding.

  • Processing cannot reach the required time per image with margin, and the computer cannot be upgraded.

  • The interface or protocol is obsolete or too slow, or the PLC has no free capacity or program access, and no interface card, I/O module or gateway solves it.

  • Drivers, software, spare parts or technical support for a legacy vision system are no longer available.

  • The current design cannot support the new requirement, for example a new defect type that needs a different imaging method.

End of support also needs planning ahead. IEC 62402 gives requirements and guidance for obsolescence management, including how to select a resolution when an item becomes obsolete [9].

Replacing one part can affect others. A new camera may need a different lens, mount, light, cable or interface card, and a faster camera may produce more data than the existing computer can handle, so assess each change as a set.

When the assessment shows that most parts need to change, a new automated visual inspection system becomes an option to compare with a legacy vision system upgrade. When the line needs non-standard imaging, mechanics or integration, the work moves to custom inspection engineering.

How Should a Retrofit Be Validated Before Production?

Validate the upgraded system on the actual line, with representative fabric, at real speed and full width, against acceptance criteria agreed before the test. Test the target defects, product changes, control signals and the behavior of the system when something fails, and record the conditions, because the result applies only to that line and those conditions.

  • Representative samples: good fabric and fabric with each target defect, including borderline cases, taken from normal production.

  • Real conditions: the normal speed range, the full width, the real light at the inspection point, and more than one roll or batch.

  • Product changes: each product the line runs, including changeovers between them.

  • Control signals: trigger timing, ready and fault signals, transfer of results, and what the line does with each result.

  • Failure behavior: what the system and the line do if a camera, light, encoder signal or network link fails. This is checked in the test; the fault handling itself is designed in the engineering phase.

  • Acceptance criteria: missed defects and false rejects measured separately, against limits agreed in advance, as described in evaluating false rejects in textile AI inspection.

For systems that classify fabric as good or defective, the VDI/VDE/VDMA 2632 guideline series includes a part on acceptance tests of classifying machine vision systems, with a sub-part on testing their classification performance [10].

Expect adjustments after the first runs. When Liu and Kato first tested their retrofit on two new rolls, the system missed defects with shapes that were not in the training data and raised false alarms caused by lint, and the model was retrained with new and reviewed data. Their work efficiency results came from a single skilled operator, which the authors say limits how far they can be generalized [1].

In the same way, a pilot or assessment result describes the line, products and conditions it was tested under, and another line, even with the same machine, needs its own check.

To define these tests and the acceptance criteria for your line, request a system assessment.

What Should You Prepare for a System Assessment?

Prepare a short description of the problem and the line, with photos, the specifications of the existing equipment and examples of the target defects. Table 2 lists what to include for each item.

Table 2. Information to prepare for a system assessment

Item What to include
Upgrade goal The problem to fix (see Table 1) and what should change after the upgrade
Machine Photos of the inspection area and fabric path, a layout or drawing, make and model
Cameras and lenses Model, resolution, interface, lens, mounting position and working distance
Lighting Type, position and angle, age, and any shielding from room light
Encoder and sensors Encoder type and where its signal is available; other sensors on the line
Processing and software Computer, operating system, inspection software and version, support status
Controls PLC model, free I/O, protocols and network, and who can change the program
Line and fabric Speed range, width range, fabric types and how often products change
Defects Target defect types, the smallest size that matters, example images, and how the plant names and grades them
Current results What is missed, what is falsely flagged or rejected, and how this is known today
Space and access Free space above and below the fabric, and access for maintenance
Action after detection Alarm, stop, marking or records, and where on the line each one happens

Swipe to see the full table

A written requirement specification helps the plant and the supplier agree on what the system must do. VDI/VDE/VDMA 2632 Part 2 supports the preparation of requirement and system specifications for machine vision and puts particular emphasis on describing influencing factors and their effects, so that they can be identified early in planning [11].

Send photos of the inspection area, the specifications of your current cameras, lights and controls, the line speed and fabric width, and examples of the defects you need to find. AI-Innovate will use them to answer three questions: what can be kept, what is limiting inspection and what needs to change. Existing equipment is assessed before any replacement is considered, and no reuse, cost, downtime or detection result is promised before the assessment.

Request a System Assessment

Frequently Asked Questions

Do we need to replace our existing cameras to add AI inspection?

Not by default. You can reuse existing machine vision cameras when tests show that they capture the target defects clearly at full width and line speed, and that their interface and drivers work with the new software. Replace or add cameras only where a test shows a limit, such as too little resolution, too low a line rate or an unsupported interface.

Can a new vision system communicate with an older PLC?

It can if the PLC has free inputs and outputs, supports a protocol the vision system also supports, or can be reached through a gateway. Legacy equipment often uses a mix of older protocols, which creates demand for adapters and gateways [6]. Check the free I/O, the supported protocols and access to the PLC program before you plan the connection.

Does GenICam or GigE Vision guarantee that an old camera will work with a new system?

No. These standards make the software connection easier: GigE Vision defines how compliant cameras connect over Ethernet and uses GenICam to describe their features [5]. Neither one covers whether the camera’s resolution, line rate, optics, lighting or bandwidth meet the new requirement, or whether a given software package supports that camera and that version of the standard.

What information should we collect before requesting a retrofit assessment?

Start with the problem you want to fix and what should change after the upgrade. Then collect photos and drawings of the inspection area, the models and settings of the existing cameras, lenses and lights, the encoder and PLC details, the line speed and fabric width range, the target defects with their sizes and example images, the products that run on the line, the installation space, and what has to happen after a defect is found. Table 2 lists these items in more detail.

References & Sources

  1. Liu, M., Kato, S. A Human-in-the-Loop Automated Fabric Inspection System: A Case Study on Retrofit Implementation and Work Efficiency. Journal of Fiber Science and Technology, 82(4), 2026, pp. 76 to 83. doi:10.2115/fiberst.2026-0008
  2. Wang, J.-H., Min, Y., Xiong, J.-Q., Fang, M., Mohd Rahim, M.S., Chen, D.-L. Novel online fabric color difference detection system based on machine vision. Scientific Reports, 16, 28554, 2026. doi:10.1038/s41598-026-58724-3
  3. European Machine Vision Association. EMVA 1288, Standard for Measurement and Presentation of Specifications for Machine Vision Sensors and Cameras, Release 4.0. Standard page
  4. European Machine Vision Association. GenICam, Generic Interface for Cameras. Standard page
  5. Association for Advancing Automation (A3). GigE Vision Standard. Standard page
  6. Alqoud, A., Schaefer, D., Milisavljevic-Syed, J. Industry 4.0: a systematic review of legacy manufacturing system digital retrofitting. Manufacturing Review, 9, 32, 2022. doi:10.1051/mfreview/2022031
  7. VDMA and OPC Foundation. OPC 40100, OPC UA for Machine Vision, companion specification series. Specification overview
  8. ISO 13849-1:2023, Safety of machinery, Safety-related parts of control systems, Part 1: General principles for design. Standard page
  9. IEC 62402:2019, Obsolescence management. Standard page
  10. VDI/VDE/VDMA 2632, Machine vision guideline series, Part 3: Acceptance test of classifying machine vision systems, and Part 3.1: Test of classification performance. VDMA overview of the series
  11. VDI/VDE/VDMA 2632 Part 2:2024-11, Machine vision: Preparation of a requirement specification and a system specification. Standard page